Armored Security Cabinet Technical Specifications

ARMORED SECURITY SPECIFICATIONS

PRODUCTION DIMENSIONS Production based on requirement.
HEIGHT 2500mm max. Height (including parapet)
METAL PARTS ST 37
CEMENT BOARD TSE 634-2
GLASS WOOL TS 901
POLYSTYRENE FOAM TS 7316

TECHNICAL DATA

EARTHQUAKE CONDITIONS 1st Degree Earthquake conditions.
CLIMATE CONDITIONS Suitable for 3rd climate zone.
SNOW LOAD 200 Kg/m²
WIND SPEED 130 Km/Hour(must be fixed to the ground)
TRANSMISSION COEFFICIENT OF EXTERNAL WALL K:0.50 Kcal/m2hc
ROOF TRANSMISSION COEFFICIENT K:0.69 Kcal/m2hc
FLOOR HEAT TRANSFER COEFFICIENT K:0.68 Kcal/m2hc
CHASSIS LOADING CAPACITY 200 Kg/m²

FLOOR

FLOOR COATING 2. mm thick PVC vinyl as main floor covering laid over 16 mm thick unflamable cement board.
EXTERIOR WALL
System Welded steel structure reinforced with specially shaped box profiles.
Armour:First, steel structure is prepared with the strong steel profiles , then covered by armour steel. Protection Level is BR7.
Interior Coating; 8 mm cement board applied on steel armour. (PVC wainscot is used in Cabins with WC). Also different types of coating materials can be used such as waterproof fiberboard with aesthetic appearance.
Wall coating; 40 mm thickness, 10 kg/m³ Polystyrene foam (EPS) with fire class B1; full heat insulation, Rockwool or glasswool can be applied based on requirements.
Exterior coating;12 mm thick Wooden or Stone appereance coating cement boards can be apllied on steel armour.

ROOF

ROOF SYSTEM Produced by special shaped construction and one piece carrier profiles and also single slop roof that prevents harmful objects from staying above it.
ROOF INSULATION 80 mm thickness glasswool (14 kg/m³)
INTERIOR CLADDING PVC wainscot (8mm cement board can be used optionally ) (PVC wainscot is used in Cabins with WC)
EXTERIOR CLADDING Armour Steel with BR7.level of protection.

DOORS

EXTERIOR DOOR Made of BR7 armour steel. An observation glass exists on the door and is made of 300×400 BR6. Door dimensions are 830×1950 mm.
INTERIOR DOOR American wooden door with 80*200 dimensions.
WINDOWS
EN 1063 BR6 NS Bulletproof . Weight 85 kg / m2. Glasses have bullet resistance certificate given by the international organizations accredited laboratory of TÜV Rheinland Company . Tough polycarbonate drawn based. Glass thickness is 40 mm . It can be manufactured in any size. The frame is made of special steel armor BR7 class which makes special frame .

PAINTING

EXTERIOR External surfaces are painted with the desired color. Silicone-based exterior paint.
DOOR FRAME Rapid primer single layer.
METAL PARTS Rapid primer single layer.
ELECTRICAL INSTALLATION(Flush Mounted)
SYSTEM Each room has a switch, a socket , a phone socket .Aditionally,spot lighting is used on the 4 corner of eaves.
INSTALLATIONS Electric power 2000 W. 220 Volt power for sockets. 3×2,5 mm for lighting 2×1.5 mm TSE certificated NYM cables are used. All installation materials have TSE certificate .
OTHER Cabin air ventilation and exterior lighting are included. Optionally, emergency siren sound also can be applied.

SANITARY INSTALLATIONS

ACCESORIES TSE certified materials are used.
PLUMBING TSE certified materials are used.
WASTE WATER TSE certified PVC materials are used.
EXTERNEL CONNECTION
The concrete foundation should be 20 cm wider than the cabin and the ground assembling of cabin, electricity, clean water and waste water connection are responsibiliry of the customer.

LIFTING

Cabin can be lifted from corner lugs by steel ropes.Cabin weight could vary according to the size.

LEVEL OF PROTECTION

AMMUNITION PROTECTION VELOCITY

9×19 124 gr FMJ BR2 ( DN 1502 ) 400 m/s
357 MAGNUM 158 gr BR4 ( DN 1502 ) 430 m/s
7.62X51 NATO Ball (G3) BR6 ( DN 1502 ) 830 m/s
7.62X51 WC (Tungsten C) STANAG 4569 LVL-3 930 m/s
7.62X39 AP (AK-47) STANAG 4569 LVL-2 725 m/s

PREFABRICATED Building Technologies has the right to make modifications in the Technical Specifications.